DOI:

Received April 22, 1999,Revised July 15, 1999, Accepted , Available online

Volume 12,2000,Pages 290-295

  • Summary
  • References
  • Related Articles
This paper describes the application of wet air oxidation to the treatment of desizing wastewater from two textile companies. A two-liter high temperature, high pressure autoclave reactor was used in the study. The range of operating temperatures examined was between 150 and 290℃, and the partial pressure of oxygen ranged from 0. 375 to 2.25 MPa. Variations in pH,CODCr and TOD content were monitored during each experiment and used to assess the extent of conversion of the process. The effects of temperature, pressure and reaction time were explored extensively. More than 90 % CODCr reduction and 80 % TOC removal have been obtained. The results have also been demonstrated that WAO is a suitable pre-treatment methods due to improvement of the BOD5/CODCr ratio of desizing wastewater. The reaction kinetics of wet air oxidation of desizing wastewater has been proved to be two steps, a fast reaction followed by a slow reaction stage.

Copyright © Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. and Science Press. All rights reserved.京ICP备05002858号-3