DOI:

Received April 22, 1998,Revised June 22, 1998, Accepted , Available online

Volume 12,2000,Pages 98-102

  • Summary
  • References
  • Related Articles
A solid phase extraction procedure of methomyl and thiodicarb from environmental water was presented. This method utilizes a 40—60 mesh activated carbon cartridge and high performance liquid chromatography (HPLC). The 40—60 mesh activated carbon works faster and yield higher adsorption efficiency. Detection limits of methomyl and thiodicarb in environmental water are 0 1 μg/L and 0 2 μg/L, respectively. Average recoveries of fortified methomyl and thiodicarb in water are in the range of 90 7%—98 8% and 88 9%—103 6%, respectively. The relative standard deviations are lower than 7%. This method is simple, rapid, accurate and precise.

Copyright © Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. and Science Press. All rights reserved.京ICP备05002858号-3